MECHANISM TROUBLESHOOTING GUIDE
89
AUTO STOP.
(PLAY/CUE/REV)
Are there T/up and supply reel
pulses.
In Play/Cue/Rev is the pinch
roller in contact with the capstan
shaft.
Replace Reel Sensor.
Is the output of DFG, DPG OK?
Check aligment positions (page 79)
Check spring Pinch.
Replace Drum Motor.
Check Servo, Syscon.
Check the Syscon, µ-COM.
No cassette loading.
Insert the cassette.
Check Cassette Carry Assembly.
Is there variation for F/L S/W
Output?
(In Tape with REC Tab
“L”“H”“L”)
(In Tape without REC Tab
“L”“H”“L”“H”)
Does the F/L S/W work normally?
Does the lever S/W work
normally.
Check Syscon Circuit.
Check Syscon Circuit.
Replace F/L S/W.
YES
YES
YES
YES
YES
YES
NO
NO
NO
NO
NO
NO
YES