1. Servo Adjustment
1) PG Adjustment
MODE MEASUREMENT POINT ADJUSTMENT POINT SPECIFICATION
PLAY VIDEO OUT 'PLAY' KEY (SET)
6.5H ± 0.5H
(TTV-P1) H/SW (W502, W503) 'O' KEY (REMOCON)
• Adjustment Procedure
1. Insert the PAL SP Test Tape (TTV-P1) and play.
Note - Adjust the distance of X, pressing the Tracking(+) or Tracking(-) when the ATR is blink after the
PAL SP Test Tape is inserted.
2. Connect the CH1 of the oscilloscope to the H/SW (W502, W503) and CH2 to the Video Out for the VCR.
3. Trigger the mixed Video Signal of CH2 to the CH1 H.SW (W502, W503), and then check the distance (time
difference), which is from the selected A(B) Head point of the H.SW(W502, W503) signal to the starting
point of the vertical synchronized signal, to 6.5H ± 0.5H (416µs, 1H=64.0µs).
• WAVEFORM
H/SW
6.5H(616µs)
Composite
VIDEO
+